delux
Joined: 28 Jan 2010 Posts: 9
|
Posted: Tue Sep 07, 2010 9:01 pm Post subject: Snippet Manager |
|
|
If I try to add a snippet titled "prn" (without quotes), I get an error message below. However, if I change the name it works fine.
SQL Prompt cannot save this snippet to the folder:
C:\ Users\<profile>\AppData\Local\Red Gate\SQL Prompt 4\Snippets
Check that the folder is not read-only, or that it has not been deleted or renamed. |
|
| Back to top |
|
 |
CodantiM
Joined: 29 Jun 2007 Posts: 180
|
Posted: Wed Sep 08, 2010 5:29 pm Post subject: |
|
|
PRN is a reserved file name in DOS/Windows that references your printer, so I suspect that is the problem.
I would have though having the ".sqlpromptsnippet" extension would have prevented the problem, but I guess not.
There are a number of other reserved names, for example COM1, LPT1, etc. that can't be used. |
|
| Back to top |
|
 |
delux
Joined: 28 Jan 2010 Posts: 9
|
Posted: Wed Sep 08, 2010 5:32 pm Post subject: |
|
|
Wow, I guess I've just never tried to name something that. I just tried to create a file prn.txt and it did not work. Good catch!
Thanks! |
|