Red Gate forums :: View topic - Profiling on Windows 2003 not working
Return to www.red-gate.com RSS Feed Available

Search  | Usergroups |  Profile |  Messages |  Log in  Register 
Go to product documentation
ANTS Profiler Previous Versions
ANTS Profiler Previous Versions forum

Profiling on Windows 2003 not working

Search in ANTS Profiler Previous Versions forum
Post new topic   Reply to topic
Jump to:  
Author Message
mmodra11



Joined: 01 May 2009
Posts: 2

PostPosted: Fri May 01, 2009 8:49 pm    Post subject: Profiling on Windows 2003 not working Reply with quote

I just got a trial of ANTS 4.3 and tried to put it on a test server - a Windows 2003 SP 2 box running IIS 6.

I tried to run up the profiler and select ASP.NET web application (hosted in IIS) but it threw up an error box saying

The version of Windows Server 2003 you have installed does not include full IIS support so you cannot profile ASP.NET applications running on IIS. We have detected that you are running {0}. Upgrade your operating system edition to enable IIS support.

Problem is that the error message doesn't say what it detected or what I need. Any pointers?

Thanks
Mark
Back to top
View user's profile Send private message
Brian Donahue



Joined: 23 Aug 2004
Posts: 6668

PostPosted: Mon May 04, 2009 12:48 pm    Post subject: Reply with quote

Hi Mark,

ANTS Profiler will not profile web applications hosted in Windows 2003 Web Edition because that platform is singled out as unsupported in ANTS Profiler's code. After a brief look into it, we had concluded that there was no reason we could find not to support it, so the next version will work with Web Edition.

In the meantime, you can use the Development Web Server option if it is available to use.
Back to top
View user's profile Send private message
mmodra11



Joined: 01 May 2009
Posts: 2

PostPosted: Mon May 04, 2009 3:56 pm    Post subject: Thanks Reply with quote

Hi Brian...

Thanks for the response. Unfortunately, the Dev Web Server option isn't really possible, given the number of moving parts (isapis, mapped virtual dirs, etc).

When will the newer version allowing Windows 2003 Web Edition be available? I can retry it then.

Thanks
Mark
Back to top
View user's profile Send private message
StephenC



Joined: 15 Oct 2007
Posts: 315
Location: Cambridge

PostPosted: Mon May 04, 2009 5:00 pm    Post subject: Reply with quote

Hi there,

we are trying to get this in place for the Beta of V5 which will be available within 1 - 2 weeks. If that doesn't happen then the final release will be quite soon after that.

I'll drop a post on here when it's available.

Regards,

Stephen
Back to top
View user's profile Send private message
Chris.Allen



Joined: 12 Mar 2009
Posts: 591

PostPosted: Wed May 06, 2009 1:23 pm    Post subject: Reply with quote

In the meantime, anyone having this same problem may use this earlier version of ANTS 4.

ftp://support.red-gate.com/patches/ants_profiler/ANTS_Profiler_4.1.0.45.exe
Back to top
View user's profile Send private message
Display posts from previous:   
Reply to topic All times are GMT + 1 Hour
Page 1 of 1

 
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum


Powered by phpBB © 2001, 2005 phpBB Group